第一篇:地铁暗挖车站土方开挖施工作业指导
厦门市轨道交通2号线一期工程土建2标 【建业路站、湖滨中路站、体育中心站、育秀东路站】
地铁暗挖车站土方施工作业
指导书
编制:
审核:
审批:
厦门市轨道2号线二标项目部
二O一五年八月
厦门市轨道2号线二标 施工作业指导书
目录 编制目的(黑体四号)···························································································2 编制依据 ·············································································································3 适用范围 ·············································································································4 施工方法及工艺要求 ······························································································
4.1施工工艺流程 ·······························································································
4.2.施工方法 ··································································································5 质量保证措施 ·······································································································6 安全、文明施工保证措施 ·······················································································7 环境保护措施 ······································································································
厦门市轨道2号线二标 施工作业指导书
地铁暗挖车站土方施工作业指导书 编制目的
为使施工人员充分了解施工图纸及工程特点,明确施工任务、操作方法、质量标准及安全措施,有效科学组织施工,确保暗挖车站土方的施工质量达到设计及施工规范要求,针对本工程施工特点,特制定本作业指导书。编制依据
1、设计文件、设计施工图及变更图
2、《厦门市轨道交通2号线一期工程施工图设计系统对土建的要求》(中铁第四勘察设计院集团有限公司,2014.10)
3、建筑基坑支护工程技术规程(GB120-99)
4、建筑地基基础工程施工质量验收规范(GB50202-2002)
5、建筑地基处理技术规范(JGJ79-2002)
6、建筑工程施工质量验收统一标准(GB50300-2001)
7、地下铁道工程施工及验收规范(GB50299-2003)
8、《建筑结构荷载规范》(GB50009-2012)
9、《建筑基坑工程技术规范》(YB9258-97)
10、《建筑基坑支护技术规程》(JGJ120-2012)
11、《地下铁道工程施工及验收规范》GB50299-1999
12、福建省标准《建筑地基基础技术规范》(DBJ13-07-2006)
13、《厦门市轨道交通2号线一期工程施工图设计》 适用范围
适用于2号线二标的建业路站、湖滨中路站、体育中心站以及育秀东路站及其附属工程的土方开挖施工。施工方法及工艺要求
盖挖逆作法是由地面向下开挖至一定深度后,先施工围护结构、中间桩和柱、主体结构顶板,然后在顶板的保护下从上向下开挖土体,并从上至下施作主体结构的侧墙、中板、横梁、纵梁、底板等。施工原则为:分区、分层、分段、分块,对称均衡开挖,厦门市轨道2号线二标 施工作业指导书
边挖快支,严禁超挖,快速封闭底板,做好防水。
4.1施工工艺流程
盖挖施工工艺流程图
4.2.施工方法 4.2.1主要施工步骤
施工准备—测量放线—围护结构施工—中间柱施工—施工结构顶板—回填
土、恢复路面—自上而下挖土—自上而下施工主体结构。
4.2.2施工工艺流程
开挖施工工艺流程如下图所示
厦门市轨道2号线二标 施工作业指导书
施工工艺流程
4.2.3施工准备
1)
完成地质补勘专项工作。
2)
基坑范围内地表建筑物已清除,地下管线已进行迁改或釆取了保护措施,作业面已具备施工条件。
3)
相应方案已编制并审批完毕,手续齐全。
厦门市轨道2号线二标 施工作业指导书
4)
已按照施工方案,合理安排了施工人员、材料、机械设备等。4.2.4施工测量放线与控制
依据甲方提供的平面、高程控制点(经复核无误)进行本工程的平面及高程控制网的布设,布设完毕后及开始进行施工放样,放样结果须经监理及第三方测量单位复核。
1)
施工放样前将施工测量方案报告监理审批。内容包括施测方法、操作规程、观测仪器设备的配置和测量专业人员的配备等。
2)
固定专用测量仪器和工具设备,建立专业测量组,专人观测和成果整理。3)
建立测量复核制度,按“三级复核制”的原则进行施测。每次施测后,须经测量工程师及技术主管复核。
4)
施工所用的导线点、水准点、轴线点要设置在工程施工影响范围之外、坚固稳定、不易受破坏且通视良好的地方。定期对上述各桩点进行检测,测量标志旁要有明显持久的标记或说明。定期对导线点、水准点进行复核。
5)
用于本工程的测量仪器和设备,应按照规定的曰期、方法送到具有检定资格的部门检定和校准,合格后方可投入使用。
6)
用于测量的图纸资料,测量技术人员必须认真核对,必要时应到现场核对,确认无误无疑后,方可使用,如发现疑问作好记录并及时上报,待得到答复后,才能按图进行测量放样。
7)
原始观测值和记事项目,应在现场用钢笔或铅笔记录在规定格式的外业手簿中。测量技术人员要认真整理内业资料,保证所有测量资料的完整。资料必须一人 计算,另外一人复核。抄录资料,亦须认真核对。
8)
积极和测量监理工程师进行联系、沟通和配合,满足测量监理工程师提出的测量技术要求及意见,并把测量结果和资料及时上报监理及第三方监测单位,测量监理工程师经过内业资料复核和外业实测确定无误后,方可进行下步工序的施工。
4.2.5 围护结构施工
在做好各种准备工作后,将施工基坑围护结构,围护结构有钻孔灌注桩、地下连续墙等承载能力大、刚度大的支护结构,具体施工作业,根据施工图的围护结构类型,见相应的作业指导书。
4.2.6基坑降水
根据基坑围护结构的不同,选择进行坑内降水和坑外降水。
厦门市轨道2号线二标 施工作业指导书
降水方法适用条件:开挖基底低于地下水位的基坑,如果环境条件允许,应根据基坑地质条件及工程特点,釆取措施降低地下水位至开挖面下50-100cm,然后才能开挖。基坑降水的主要方法有管丼降水、轻型丼点降水、喷射丼点降水、电渗丼 点降水。电渗丼点降水一般用于淤泥或淤泥质粘土等渗透系数非常小的地层;喷射丼点降水深度大,但需要双层丼点管,安装工艺复杂,造价高;轻型丼点设备简单,安装快捷,是常用方法,但降水速度慢,影响半径小;管丼降水深度大,降水速度 大。
管丼降水一般布置在基坑开挖范围外或基坑内部边坡平台上,分为疏干丼和降压丼。疏干丼用于降低潜水水位,降压丼用于降低承压水位。基坑开挖中一般釆用管丼疏干丼降水,并可以先开挖地下水位50cm以上的土方,然后形成边坡平台,在基坑内部边坡平台上进行丼点降水,降低造价。
4.2.7中间柱施工
中间柱是盖挖逆作法施工的地下车站之重要的工程构件。中间柱由中柱及基础中桩两部分组成,一般为永久立柱,为主体结构的承载结构。
为了减少围护结构及中间桩柱的入土深度,可以在做围护结构和中间桩柱之前,用暗挖法预先做好它们下面的底纵梁,以扩大承载面积。当然,这必须在工程地质条件允许暗挖施工时才可能实现,而且在开挖最下一层土和浇注底板前,由于围护结构和中间桩柱都无入土深度,故必须釆取措施,如设置横撑以增加它们的稳定性。
4.2.8施工顶板及顶板回填恢复路面
顶板回填碾压密实度应满足地面工程设计要求,如设计无要求时,按下表要求。基坑回填碾压密实度表
每层回填做成不少于2%的横坡和向未填方向形成纵下坡,以利雨期排水。回填时集中力量,取、运、填、平、压各环节紧跟作业,抓紧晴天突击作业。
4.2.9基坑开挖
基坑开挖在降水施工完毕并降水20天后,进行土方施工。由于盖挖法施工时已 经
厦门市轨道2号线二标 施工作业指导书
限定了出土口的位置,土方开挖必须根据出土口的位置,向下、左右单方向推进 开挖,基坑开挖竖向分层、对称平衡开挖。
开挖过程中应充分发挥机械的施工效率。一个工作面上,釆用小型挖掘机进行作业,并配置小型的出土车进行出土作业,每台挖机均设专人指挥。
1)
基坑顶有动载时,坑顶缘与动载间应留有1m的护道,如地质、水文条件不良,或动载过大,应进行基坑开挖边坡验算,根据检算结果确定釆用增宽护道或其 他加固措施。
2)
土方开挖过程中注意保护坑内降水丼,确保降水、排水系统的正常运转。3)
开挖中须遵循“在完成上步支护前不得继续开挖”的原则,当开挖一段后及时网喷支护,然后进行下一段的开挖,直至支护完毕。
4)
基坑开挖过程中严禁超挖,基坑纵向放坡不得大于安全坡度,严防纵向滑坡。(安全坡度须按照设计图纸规定取值,无规定时,参照《建筑边坡工程技术规范》
GB50330-2002 进行计算)
5)
加强基坑稳定的观察和监控量测工作,以便发现施工安全隐患,并通过监测反馈及时调整开挖程序。
6)
为防止超欠挖,基坑内设计坡面0.2m范围内的土方釆用人工开挖。⑹各项技术、质量资料齐备,操作、安全已交底,规章制度已建立。4.2.10基底处理
当基底以下地质不符合地基承载力要求时,应通过变更设计釆取处理措施,处理方法随地基土质不同而异。
如遇到地基软硬不均、溶洞、裂隙、泉眼等特殊情况,应釆用换土法、土桩法、砂桩法、重锤夯实法、强夯法、旋喷法、塑料排水法、振动水冲法、化学液体加固法等特殊的处理方法。对于粉质土、黄土、砂土、小粒径等基底,也可釆用旋喷桩加固。
4.2.11基坑监测
为了基坑开挖施工的安全,保证工程质量,为使周围已有建筑物、市政设施、地下管线等不受损伤、少受干扰,必须对基坑开挖全过程进行系统监测。
基坑放坡开挖监测工作主要为:地表沉降值、坡面位移值、地下水位监测值。通过监测,随时掌握边坡的稳定状态、安全程度,为设计和施工提供信息。
1)
基坑土体、地表建筑物及地下管线沉降观测:釆用精密的水准仪进行量测。主
厦门市轨道2号线二标 施工作业指导书
要釆用精密水准测量方法进行,沉降观测点直接设置在被观测对象的特征点上,并在远离基坑或稳定的位置设置基准点。施工初期每天观测1-2次,施工后期可每 隔7天观测1次。
2)
降水观测:利用丼点降水丼作为水位观察丼,釆用水位仪进行监测,施工出去每天观测1次,后期可1-2天观测一次。根据水位变化情况调整抽水泵的开闭。
3)
在基坑开挖支护施工过程中,每次监测结果及时向项目部和监理工程师报告。提交阶段成果资料包括:沉降观测成果表、水平位移观测成果表、水位监测成果表,当基坑变形出现异常情况时,加密监测次数,对监测数据进行分析研究,提出基坑安全的合理化建议。
4.2.12 施工注意事项
1)
施工过程中严格遵循“从上到下、分层分块、分区分段、阶梯流水开挖”的原则,落实“分层、分步、对称、平衡、限时”五个要点,保证“竖向分层、纵向分区分段、随挖随支护”。
2)
对测量控制定位桩、水准点应注意保护。挖土、运土、机械行驶时,不得碰撞,并应定期复测检查其是否移位、下沉;平面标高和边坡坡度应符合设计要求。
3)
配备足够人力、物力、机械,加强工序之间的衔接,尽量缩短基坑暴露时间。4)
降水丼在施工过程中要做好保护,避免因损坏而影响基坑降水。5)
基坑边坡,在开挖后要防止扰动或被雨水冲刷,造成失稳。
6)
基坑开挖后,如不能很快的浇筑垫层,应预留150-250mm厚土层,在施工下道工序前再挖至设计标高。
7)
深基坑开挖或降低地下水过程中,应定期对邻近建筑物、道路、管线及支护系统进行观察和测试,是否发生变形、下沉或移位,如发现异常情况,应釆取防护措施。质量保证措施
1)
建立质量保证体系,现场技术管理和质量管理各方面管理制度。
2)
认真做好图纸会审,设计交底,施工技术交底,工程技术资料档案和技术培训等方面工作,为质量提供技术保证。
3)
测量放样实行三级放样复核制度,并经监理复测,确认。4)
内业资料,做到及时、准确、完整、标准。
5)
每段基坑底挖土结束后,按隐蔽工程组织验收,若不符合标准,应及时整改,厦门市轨道2号线二标 施工作业指导书
并加强中间检查,督促施工人员严格按规范施工。
6)
基坑开挖过程中,如发现地面沉降超限、坡体位移超限等异常情况,立即停止施工,并分析原因进行处理,情况紧急时必须及时报告监理、设计单位、业主等。
7)
土方机械,不得碰撞和碾压已支护完毕的边坡及降水丼。
8)
基坑支护必须紧跟开挖,必须按照边挖边支护的原则,如支护施工延后,挖土施工应相应顺延。
9)、常见问题及纠偏预防措施 9.1边坡塌方
在挖方过程中或挖方后,边坡土局部或大面坍塌。
1)
结合开挖面土体力学特性,按照设计规定的边坡坡度确定开挖边坡坡度。2)
釆用机械挖方时,应根据不同土质,不同的坡度值,放出基坑边线,边挖边修坡,每次修坡深度不超过1m。
3)
在坡顶堆土时,土堆至挖方上边缘的距离要根据挖方深度、堆积土数量和土的特性确定。任何情况下不得小于1.2m,土堆高度不得超过1.5m。
4)
在受地下水、地表水影响的基坑,应根据不同深度、不同土质确定排水方法。9.2基坑超挖、基底扰动
基坑开挖后,地基不平,使局部或全部地基面高程低于设计标高,基底原状土受到扰动。
1)
加强测量复核,要设高程控制桩,指派专人负责经常复测标高; 2)
机械挖方时须由专人指挥,当机械挖至还剩30cm时,应由人工开挖。3)
当出现超挖或扰动时,及时报告监理、设计等单位,一起解决处理。9.3管道破裂
车站施工时经常遇到有地下管线,因此在施工中须釆取以下措施对其变形加以控制:
1)
施工前认真核实与施工有关联的地下管线资料,调查清楚各管线类型、规格、埋深、材质、接头形式、节长和管线基础等资料,并做好详细的支吊、保护方案,经监理批准后实施管线支吊。
2)
支吊加固的不同管线建立与各自产权单位的联系卡片,向管理单位咨询支吊保护的技术要点,对可能破坏的各类管线,结合施工现场及工程施工阶段分别制定相应的 厦门市轨道2号线二标 施工作业指导书
应急措施,并取得相应管理单位的认可。
3)
严格按照施工组织设计施工,根据管线的分布及特点,建立各自的安全区域,挂牌标志,严禁机械设备碰撞。
4)
对各种管线进行全程监测,并根据监测结果及时反馈,指导施工,确保各类管线闸阀始终处于正常工作状态。一旦出现渗水、漏气等异常情况,立即查明原因、釆取措施,并与管理单位取得联系,确保管线安全。
5)
不良地质地段必须釆取特殊的施工技术措施,如地层改良、缩短循环进尺等,以防沉降超限。
9.4基坑开挖引起涌砂或坑底底鼓失稳
基坑涌砂或基底底鼓失稳主要是因为基坑内外水位差较大,桩未进入不透水层或嵌固深度不足,坑内降水引起土体失稳。对此,釆用以下处理措施:
1)
立即停止基坑内降水或挖土。2)
对基底实施注浆加固。3)
必要时可进行基坑堆料反压。4)
加强基坑外降水。9.5 触电事故
1)
现场临时用电线路的安装、维修、拆除应由取得特殊工种上岗证的专职电工进行操作。
2)
所有电线路釆用“三相五线制”,机电设备必须按“一机一闸一漏一箱”设保护装置。场内禁止使用裸体导线,架设的电力线路应符合有关规定要求。
3)
变压器设置围栏,设门加锁,专人管理,悬挂警示牌,变压器必须设接地保护装置,其接地电阻不得大于40。
4)
室内配电拒、配电箱前设绝缘垫,并安装漏电保护装置。各类电器开关箱和电器设备,按规定设接地或接零保护装置,禁止电源开关箱内存放工具、杂物,并加锁。
5)
检修电器设备时必须停电作业,电源箱或开关握柄上应挂有警示牌或派人看 管,严禁带电作业。
6)
施工现场用的手持照明灯使用36V以下的安全电压,在暗挖施工中使用的照明灯必须使用12V以下的安全电压。
7)
生活照明用电严禁个人私自拉接线路,私自安装插座和大功率电器。
0
第二篇:地铁明挖车站土方开挖施工作业指导
厦门市轨道交通2号线一期工程土建2标 【建业路站、湖滨中路站、体育中心站、育秀东路站】
地铁明挖车站土方开挖施工
作业指导
编制:
审核:
审批:
厦门市轨道2号线二标项目部
二O一五年八月
厦门市轨道2号线二标 施工作业指导书
目录 编制目的 ·············································································································2 编制依据 ·············································································································3 适用范围 ·············································································································4 施工方法及工艺要求 ······························································································
4.1施工工艺流程 ·······························································································4.2.施工方法 ··································································································5 质量保证措施 ·······································································································6 安全、文明施工保证措施 ························································································7 环境保护措施 ·······································································································
厦门市轨道2号线二标 施工作业指导书
地铁明挖车站土方施工作业指导书 编制目的
为使施工人员充分了解施工图纸及工程特点,明确施工任务、操作方法、质量标准及安全措施,有效科学组织施工,确保明挖车站土方的施工质量达到设计及施工规范要求,针对本工程施工特点,特制定本作业指导书。编制依据
1、设计文件、设计施工图及变更图
2、《厦门市轨道交通2号线一期工程施工图设计系统对土建的要求》(中铁第四勘察设计院集团有限公司,2014.10)
3、建筑基坑支护工程技术规程(GB120-99)
4、建筑地基基础工程施工质量验收规范(GB50202-2002)
5、建筑地基处理技术规范(JGJ79-2002)
6、建筑工程施工质量验收统一标准(GB50300-2001)
7、地下铁道工程施工及验收规范(GB50299-2003)
8、《建筑结构荷载规范》(GB50009-2012)
9、《建筑基坑工程技术规范》(YB9258-97)
10、《建筑基坑支护技术规程》(JGJ120-2012)
11、《地下铁道工程施工及验收规范》GB50299-1999
12、福建省标准《建筑地基基础技术规范》(DBJ13-07-2006)
13、《厦门市轨道交通2号线一期工程施工图设计》 适用范围
适用于2号线二标的建业路站、湖滨中路站、体育中心站以及育秀东路站及其附属工程的土方开挖施工。施工方法及工艺要求
明挖法是指在维护结构和支撑体系的保护下,自地面向下依次开挖,挖至设计标高后,在基坑底部由下向上施作主体结构,待主体结构施工完毕后回填土方,恢复路面和管线。
厦门市轨道2号线二标 施工作业指导书
4.1施工工艺流程
明挖施工工艺流程图
4.2.施工方法
4.2.1主要施工步骤
施工准备—测量放线—围护结构施工—内丼点降水(或基坑底 土体加固)-第一层开挖-设置第一层支撑体系-第n层开挖-设置第n层支撑体系—最底层开挖—浇筑底板砼—最下层支撑拆除—砼内衬浇筑—自上而下逐步拆支撑—顶板砼浇筑—回填土方—恢复路。
4.2.2施工工艺流程
4.2.2.1开挖施工工艺流程如下图所示
厦门市轨道2号线二标 施工作业指导书
土方开挖施工工序图
①土方开挖采用分层、分块、对称、平衡开挖和支撑的顺序,施工时严格控制各工序的时限,单块开挖卸载后无支撑的暴露时间不得太长,无特殊情况,单块土方开挖后必须立即组织支撑施工,缩短无支撑暴露时间。
②开挖时,挖掘机等施工机械不得碰撞支撑和维护等结构物,维护管线等设施的安全。
③开挖到基底标高以上30cm时,采用人工挖土、修平,以保护坑底土体不受施工扰动。
④开挖应根据分层、分块的流程顺序开挖,形成规则的开挖坡面,开挖坡度<1。:1.5,不得随意乱挖,留下坑洼或陡坡。
⑤坑内排水在开挖基坑施工时,在基坑底两侧及坡底开挖排水沟,在四角及每隔20m设一集水井,使地下水流汇集于集水井内,再用水泵将集水井的水排至地面排水沟,通过三级沉淀处理后,再排入污水管道。
⑥在挖土施工时,必须做好降水井的保护工作,严禁损坏降水井管,确保井管的完好。
厦门市轨道2号线二标 施工作业指导书
4.2.2.2冠梁施工工序见下图
冠梁施工工序图 ①测量放样
测量人员根据设计(外方后结构尺寸),定出冠梁中心线及边线,经监理工程师验收合格后进行开挖。
②基坑开挖
根据地质条件,基坑开挖采用挖掘机开挖并配合人工修整的方法进行。基坑内侧用反铲挖出宽1m土槽,挖至冠梁底设计标高以上20cm后,用人工开挖至冠梁底标高并找平,宽度大于冠梁平面尺寸60cm~100cm.如基底产生积水,采用集中排水法排至坑外,四周设排水沟,利用潜水泵抽水。
③破除超灌混凝土
基坑开挖完毕后,凿除墙头超灌部分混凝土,以便保证墙头质量。本工艺采用空压机、风镐破碎,严禁使用破碎锤,当破碎位置距离设计标高为5cm时,剩余部分采用人工凿除。墙头要求平整,周边不允许破坏。墙头要求平整,周边不允许破坏;当混凝土破到设计标高时观察新破除混凝土质量,如混凝土质量达不到设计要求,继续破除直到混凝土质量满足设计要求为止。地连墙顶部超灌部分混凝土凿除时要注意保护预埋件(测斜管、声测管、注浆管、钢筋应力计电线)。不要将其碰断。如发生断裂,应及
厦门市轨道2号线二标 施工作业指导书
时用布或编织袋将其封堵、覆盖,严禁让泥土落入管中。
④垫层施工
墙头处理完毕,墙头破除至设计墙顶标高后,将基底整平并夯实,然后在土质基地上铺设10cm厚M7.5砂浆垫层,起到找平和做为底模的作用。4.2.2.3混凝土腰梁、支撑施工工序见下图
当土方开挖至设计标高后,进行整平、复测标高,保证底模的平整及高程位置。同时施作基底100mm厚的混凝土垫层进行加固处理,以防模板在混凝土浇筑后发生沉降,而影响混凝土支撑的质量。
腰梁与钢筋混凝土支撑同时施工,分段分批浇筑,腰梁施工前,凿除地连墙混凝土,调直地连墙内的腰梁预埋筋,同时对接头处新老混凝土接合面按要求凿毛处理。质量保证措施
1)
建立质量保证体系,现场技术管理和质量管理各方面管理制度。
2)
认真做好图纸会审,设计交底,施工技术交底,工程技术资料档案和技术培训等方面工作,为质量提供技术保证。
3)
测量放样实行三级放样复核制度,并经监理复测,确认。4)
内业资料,做到及时、准确、完整、标准。
5)
每段基坑底挖土结束后,按隐蔽工程组织验收,若不符合标准,应及时整改,厦门市轨道2号线二标 施工作业指导书
并加强中间检查,督促施工人员严格按规范施工。
6)
基坑开挖过程中,如发现地面沉降超限、坡体位移超限等异常情况,立即停止施工,并分析原因进行处理,情况紧急时必须及时报告监理、设计单位、业主等。
7)
土方机械,不得碰撞和碾压已支护完毕的边坡及降水丼。
8)
基坑支护必须紧跟开挖,必须按照边挖边支护的原则,如支护施工延后,挖土施工应相应顺延。
9)、常见问题及纠偏预防措施 9.1边坡塌方
在挖方过程中或挖方后,边坡土局部或大面坍塌。
1)
结合开挖面土体力学特性,按照设计规定的边坡坡度确定开挖边坡坡度。2)
釆用机械挖方时,应根据不同土质,不同的坡度值,放出基坑边线,边挖边修坡,每次修坡深度不超过1m。
3)
在坡顶堆土时,土堆至挖方上边缘的距离要根据挖方深度、堆积土数量和土的特性确定。任何情况下不得小于1.2m,土堆高度不得超过1.5m。
4)
在受地下水、地表水影响的基坑,应根据不同深度、不同土质确定排水方法。9.2基坑超挖、基底扰动
基坑开挖后,地基不平,使局部或全部地基面高程低于设计标高,基底原状土受到扰动。
1)
加强测量复核,要设高程控制桩,指派专人负责经常复测标高; 2)
机械挖方时须由专人指挥,当机械挖至还剩30cm时,应由人工开挖。3)
当出现超挖或扰动时,及时报告监理、设计等单位,一起解决处理。9.3管道破裂
车站施工时经常遇到有地下管线,因此在施工中须釆取以下措施对其变形加以控制:
1)
施工前认真核实与施工有关联的地下管线资料,调查清楚各管线类型、规格、埋深、材质、接头形式、节长和管线基础等资料,并做好详细的支吊、保护方案,经监理批准后实施管线支吊。
2)
支吊加固的不同管线建立与各自产权单位的联系卡片,向管理单位咨询支吊保护的技术要点,对可能破坏的各类管线,结合施工现场及工程施工阶段分别制定相应的 厦门市轨道2号线二标 施工作业指导书
应急措施,并取得相应管理单位的认可。
3)
严格按照施工组织设计施工,根据管线的分布及特点,建立各自的安全区域,挂牌标志,严禁机械设备碰撞。
4)
对各种管线进行全程监测,并根据监测结果及时反馈,指导施工,确保各类管线闸阀始终处于正常工作状态。一旦出现渗水、漏气等异常情况,立即查明原因、釆取措施,并与管理单位取得联系,确保管线安全。
5)
不良地质地段必须釆取特殊的施工技术措施,如地层改良、缩短循环进尺等,以防沉降超限。
9.4基坑开挖引起涌砂或坑底底鼓失稳
基坑涌砂或基底底鼓失稳主要是因为基坑内外水位差较大,桩未进入不透水层或嵌固深度不足,坑内降水引起土体失稳。对此,釆用以下处理措施:
1)
立即停止基坑内降水或挖土。2)
对基底实施注浆加固。3)
必要时可进行基坑堆料反压。4)
加强基坑外降水。9.5 触电事故
1)
现场临时用电线路的安装、维修、拆除应由取得特殊工种上岗证的专职电工进行操作。
2)
所有电线路釆用“三相五线制”,机电设备必须按“一机一闸一漏一箱”设保护装置。场内禁止使用裸体导线,架设的电力线路应符合有关规定要求。
3)
变压器设置围栏,设门加锁,专人管理,悬挂警示牌,变压器必须设接地保护装置。
4)
室内配电拒、配电箱前设绝缘垫,并安装漏电保护装置。各类电器开关箱和电器设备,按规定设接地或接零保护装置,禁止电源开关箱内存放工具、杂物,并加锁。
5)
检修电器设备时必须停电作业,电源箱或开关握柄上应挂有警示牌或派人看 管,严禁带电作业。
6)
施工现场用的手持照明灯使用36V以下的安全电压,在暗挖施工中使用的照明灯必须使用12V以下的安全电压。
7)
生活照明用电严禁个人私自拉接线路,私自安装插座和大功率电器。
厦门市轨道2号线二标 施工作业指导书
8)
露天照明釆用防水灯头,残缺的灯头、灯泡及时更换,防止发生电击事故,严禁用金属丝代替保险丝。
9)严禁乱拉乱搭电线及各种照明灯具,带电作业的机械设备专人负责制,经常检查施工用电设施,及时处理事故隐患。安全、文明施工保证措施
1)
基坑四周用钢管设置1.5m高防护栏进行围护,并涂刷醒目标记确保施工安全。2)
开挖过程中严格按编制的施工方案进行,操作时应注意土壁的变动情况,发现裂纹或部分坍塌现象,应及时进行躲避。
3)
开挖过程中周期性对埋设的水准点进行观测,及时掌握水准点的位移和基坑沉降,确保基坑开挖安全稳定。
4)
运土道路的坡度、转弯半径要符合规范的安全规定。
5)
密切观测天气预报,暴雨或大雨来临前,停止开挖,立即对边坡进行覆盖防护。同时,及时抽排汇入排水沟内的水,尽量减少基坑积水,确保基坑安全。
6)
施工现场实施机械安全管理及安装验收制度。使用的施工机械、机具和电气设备,在投入使用前,按安全技术标准进行检测、验收,确认机械状况良好,能安全运行的,才准投入使用。制定各机械的安全操作规程,并挂牌上墙。对机械操作人员要建立档案,专人管理。使用期间,严格工前的检查制度,工作中注意观察及工作后的检查保养制度,保证机械设备的完好率和使用率。并指定专人负责维护、保养。
7)
抽水设备的电器部分必须做好防止漏电的保护措施,严格执行接地、接零和使用漏电开关三项要求。施工现场电线用架空拉设,用三相五线制。环境保护措施
1)各种车辆在施工现场禁止鸣号运输车在运输道路上禁止鸣号,为确保安全可以减低速度。
2)基坑排出的水要经过沉淀之后再排入排水沟管网。
3)夜间施工需要征得经过当地环保部门批准,要制定防止噪音的措施。4)施工现场生活区、指挥部、值班室,不允许乱倒生活垃圾、生活污水。5)施工现场要配备洒水车,保持地面潮湿,防止粉尘污染。
第三篇:暗挖地铁车站钢管柱安装施工技术
暗挖地铁车站钢管柱安装施工技术
摘 要:本文着重介绍了暗挖逆作法地铁车站主体结构钢管混凝土柱地面施工的方法。包括成孔、护壁、定位器安装、钢管柱安装、钢管柱内混凝土浇筑等环节的施工方法,以及在施工过程中不断摸索总结改进的重点环节施工经验。
关键词:地铁施工 暗挖法 钢管柱安装工程概况
南京地铁南京南站为地下两层岛侧式站台车站,主体结构采用钢筋混凝土箱体框架结构,车站长252.4m,标准段宽度47.2m,车站基坑开挖深度约为14.3m~15.6m。车站采用暗挖逆作法施工,车站共设102根钢管混凝土柱,钢管混凝土柱作为施工过程的中间支撑柱,在车站底板结构尚未封闭时,承受地下各层已施作完毕的框架结构自重和各种施工荷载,顶板封闭后,中间柱作为车站主要竖向承载和传力结构。
钢管混凝土柱基础深度分别为9m和17m,直径为1.5米,采用C35钢筋混凝土。钢管柱长度约16m,直径800mm,壁厚20mm,共102个,锚入桩基础深2m。钢管柱心填充C50补偿收缩混凝土,与顶板、中板和底板相接位置设置钢牛腿。
该区段近地表主要分布可-硬塑的粉质粘土或粘土,底部主要为风化的泥质粉砂岩和粉砂质泥岩,地形较平坦,工程地质性能良好。
施工方案
根据现场地质图以及现场实际地质情况,在粉质粘土层较厚范围钢管柱有效部位采用人工挖孔桩+桩基础采用旋挖钻机成孔;粉质粘土层浅,砂岩层厚的范围可以采用机械成孔+长大钢护筒护壁的施工方法。定位器采用人工安装。钢管柱基础混凝土灌注采用导管干灌法灌注工艺,钢管安装完毕后,向挖孔桩护壁与钢管柱之间回填细砂,然后进行钢管内混凝土浇筑。
施工步骤
3.1采用人工挖孔+机械成孔施工步骤
在粉质粘土层和杂填土较厚范围采用人工挖孔+机械成孔方案施工,人工挖孔至钢管柱底,然后采用旋挖钻机施作钢管柱基础。
施工方法见下图:
图3.1-1(钢管柱及基础施工流程图)序号图示说明序号图示说明1 人工挖孔至钢管柱底2 旋挖钻机成孔至基础桩底3 吊放钢管柱基础钢筋笼4 第一次浇筑基础混凝土至定位器下60cm5 安装定位器下定位钢板6 灌注钢管柱下桩基混凝土至定位器底7 安装钢管 柱定位器8 准确定位钢管柱9 浇筑2m高杯口混凝土10 钢管柱与护壁之间回填细砂11 浇筑钢管柱混凝土
3.2采用长大钢护桶配套机械成孔施工步骤
在地质条件好,能够满足机械成孔要求时,可以采用机械成孔。采用旋挖钻成孔至钢管柱基础底,吊安基础桩钢筋笼,浇筑混凝土至钢管柱底部,安装钢护桶,钢护桶采用8mm厚钢板制作,钢护桶安装完毕合格后,人工安装定位器、安装钢管柱、浇筑柱内混凝土等工作。
机械成孔至钢管柱基础底2 吊装基础钢筋笼3 浇筑砼至定位器下60cm4 安装钢护桶及定位器底定位钢板5 灌注基础混凝土至定位器底6 人工安装钢管柱定位器7 准确定位钢管柱,拔出钢护桶8 浇筑锚固钢管2m范围混凝土9 钢管柱与护壁之间回填细砂10 浇筑钢管柱混凝土
关键施工技术
4.1 人工挖孔桩施工技术
4.1.1 成孔工艺流程
挖孔桩施工内容主要包括:测量定位,井口防护,挖孔桩成孔,护壁施做等工序施工。人工挖孔桩成孔工艺流程见图4.1-1所示。
4.1.2 成孔工艺流程
人工挖孔桩采用分节挖土,分节支护的施作方法。挖孔前,在孔口处锁口环设置四个桩心控制点,并牢固标定,以便随时检查挖孔垂直度和孔深。护壁支模时必须吊大线锤校定。桩孔人工开挖,挖土次序为先中间后周边,弃土装入吊桶,用多功能提升架提升至地面,倒入手推车运到临时存碴场。
4.1.3 护壁的施做
挖孔桩护壁每节进尺0.5~1.0m。在开挖第一节桩孔前,先破除桩位置地面,开挖第一节桩孔,支第一节护壁模板,灌筑护壁混凝土。第一节护壁混凝土高出地面30~50cm,便于挡水和定位。第一节孔圈护壁应比下面的护壁厚100~150mm,上、下护壁间的搭接长度不得小于50mm。中心线应与桩孔轴线重合,偏移控制在0~50mm,其轴线的垂直度允许偏差不大于0.3%。每两节护壁必须进行桩的中心位置和垂直度检查一次,以保证桩的垂直度。在地质条件较好的土层中,每开挖1m深,即施工混凝土护壁,在容易发生坍塌的粉细砂层中,每开挖0.5m深,即施工混凝土护壁
随着开挖的完成,清理桩孔壁淤泥,复核桩孔垂直度和直径,按设计图纸插入竖向钢筋并保证向下预留长度为35d,再布设环向箍筋并绑扎成形,及时安设模板。护壁模板采用组合式异形钢模板,模板由四块拼装组成,模板间用U型卡连接,同时以利拆除每节护壁适当设置L形调节缝板。本护壁混凝土上部厚150mm,下部厚100mm,上节护壁的下部应嵌在下一节护壁的上部混凝土中,上下搭接50mm,桩孔开挖后应尽快灌注护壁混凝土并振捣密实。待护壁砼达到一定强度时进行拆模工作。护壁砼浇筑见图4.1-2。
4.2 机械成孔垂直度控制技术
成孔时,要确保钻机定位准确、水平、稳固。钻机定位后,用钢丝绳将护筒上口挂带在钻架底盘上,成孔过程中,钻机塔架头部滑轮组、回转器与钻头始终保持在同一铅垂线上,保证钻头在吊紧的状态下钻进。成孔直径须达到设计桩径。
当挖孔至设计深度时,对成桩孔径、桩底标高、桩位中线、垂直度、虚土厚度、嵌入深度进行全面测定,做好施工记录。
4.3 定位器安装、定位施工技术
定位器是钢管柱施工精度控制的关键工序,施工控制坚持做到安装前放线,安装后重新复核安装位置。
4.3.1 自动定位器的原理及作用
钢管柱采用上下两端同时定位法固定。钢管柱下端定位主要依赖于自动定位器,上端用花篮螺栓调节定位。自动定位器是一种预先加工的装置,精确校正其平面位置、高程和垂直度后,上端固定于挖孔桩护壁预埋钢板上,浇筑桩基混凝土后其下端锚固于桩基混凝土中。其构造特点决定了可实现对钢管柱的引渡、限定、精确定位的功能。
4.3.2 自动定位器的安装
自动定位器的安装首先在地面加工好预埋钢板和定位器支撑钢板,第一步:待基础桩混凝土达到强度后,在井口将标高控制点投测于挖孔桩护壁上,采用悬挂钢尺精确定出定位器支撑钢板顶面标高(既定位器底板底面标高),第二步:安装好支撑钢板并浇筑钢管柱基础桩剩余60cm高范围混凝土。第三步:在支撑钢板上焊接安装定位器,采用激光垂准仪以和吊线锤相结合的方法确定定位器中心。
4.4 钢管柱安装垂直度控制
4.4.1 定位器定位测量
定位器的中心点确定先从地面用锤球将桩心引至钢管柱基础顶面上,精确定出定位器的中心位置,以之为依据指导定位器的初定位安装。其后将1/20万的投点仪复核定位器中心位置,将桩心直接投测于定位器中心指挥定位器精确定位,直至安装完毕。为避免投点仪投点视镜不铅垂误差,每次投点时按90度变化四个方向,如点位均落于同一点时,即是桩心。否则会产生四个方向点A、B、C、D并行成一个四边形,此时,取四边形的中心点O,即是桩心。
4.4.2 钢管柱体吊装就位测量控制
根据孔口轴线点位,用线绳拉出孔中心点,钢管由履带吊车吊装,在管底靠近孔口位置处停止,调整吊车大臂确保钢管中心与孔中心重合,吊车大臂不动,垂直下降。
管柱一次整体吊放入孔,中间不接驳。出厂前,在上节法兰盘底加肋板上对称焊接设置一对吊耳,同时在吊耳侧加焊肋板,以确保柱体处于最不利位置时,吊耳不发生侧翻破坏现象。准备工作完成后,采用两台25吨履带吊相互配合作业。一台主吊,另一台吊车辅助吊http://www.xiexiebang.com/ http://www.xiexiebang.com/
http://www.xiexiebang.com/ 装,以防止钢管柱底部戳地变形。操作时一台吊车在钢管柱上端两点起吊钢管柱,同时另一台吊车起吊钢管柱底部,使钢管柱上端起吊过程中,其底部脱离地面。辅助吊车缓慢放绳,待钢管柱完全垂直吊离地面,且相对稳定后,将其与辅助吊车分离。对准桩位,下放钢管柱,慢插入孔,钢管柱底部可直接嵌入定位器,其管端稳固座落于定位器环行定位板上,通过复核钢管柱顶标高确定柱底与定位器的吻合程度。然后对柱上端精确定位,柱上端采用轴线重合的方法确定,既在钢管柱下吊前确定好钢管柱的轴线,根据护壁(钢护筒或人工护壁)上定位的轴线吊线锤确定钢管柱柱顶的位置。由于钢管柱下端平面位置、标高、垂直度已由定位器确定,钢管柱上端空间位置校定后,即可认为柱顶与柱底在垂直方向投影重合,钢管柱位置已精确定位。柱顶钢筋待柱芯混凝土浇筑完毕后插入固定。5 结束语
在本工程中,对定位器安装环节分解为两步骤,既多增加了安装支撑垫板工序,大大的降低了施工测量控制难度,加快了施工进度。目前,此基坑开挖工作已经完成,通过验收检查,该工程施工的钢管柱垂直度在允许的偏差范围内,柱芯混凝土完整性好,说明此施工方法切合实际,最大限度的缩短了施工工期,对于同类施工具有指导作用。
第四篇:暗挖地铁隧道施工技术研究论文
摘要:本文主要分析了西安地铁三号线青龙寺~延兴门暗挖区间复杂地质以及高深基坑情况下暗挖地铁隧道施工的方法和施工技术措施,并讨论了施工中如何提升施工的品质,提出了提升施工安全、质量、文明施工的一些具体措施,希望能够为今后的施工提供参考。
关键词:复杂地铁;高深基坑;暗挖地铁隧道;施工技术
复杂地质以及高深基坑暗挖地铁施工的过程中,降水、地层加固处理、控制沉降、预防掌子面坍塌是最为关键的一个环节,应用浅埋暗挖施工方法,一定要抓住施工的要点和方法,并构建施工的安全、质量管理体系,确保施工的有效性和合理性。
1工程概况
西安地铁三号线青龙寺~延兴门暗挖区间自陕西省微生物研究所起始,沿西影路东行至正大制药厂后,向北拐至陕西省西安监狱,最后穿过延兴门到达延兴门站,该暗挖段下穿西安正大制药厂及西安监狱。区间设置临时施工竖井及横通道一处,竖井深度达到42m,根据竖井所处的环境条件、地质条件、断面大小及深度、施工使用要求借鉴西安地区已建工程的成功经验,采用喷锚及格栅钢架联合支护。
2不良地质及特殊岩土
2.1不良地质
f7地裂缝及其分支裂缝f7-1在本工点东部西影路与经五路十字北约150m处通过,走向NEE向,倾向南,倾角约80度。本暗挖段内f7、f7-1地裂缝与左线分别在ZDK26+902.944、ZDK26+892.327相交,f7-1地裂缝与右线在YDK26+918.248相交。地裂缝与线路平面关系图
2.2特殊岩土
工点地表广泛分布有人工填土,主要为1-1杂填土,局部为1-2素填土。1-1杂填土:层厚0.10~6.70m,层底深度0.10~6.70m,层底高程422.50~440.10m;1-2素填土层厚0.30~3.90m,层底深度0.80~5.30m,层底高程421.47~439.37m。上述人工填土土质结构疏密不均,成份较复杂,工程性质差。本暗挖区间隧道顶部分布有层厚5.3~8.1m的饱和软黄土,且3-1-1新黄土(水上)e=1.061,具有大孔隙,压缩系数a1-2=0.67MPa-1,属高压缩性土,工程性质较差,浸水后工程性质易恶化,天然状态及浸水状态均会产生较大的不均匀沉降。3-1-2新黄土(水下)e=0.918,具有大孔隙,压缩系数a1-2=0.32MPa-1,中等压缩性,水位降低后将会引起较大的压缩沉降。
3施工控制关键技术
3.1洞内水位控制
无水作业是保证区间暗挖隧道施工安全的前提条件,根据工程地质及水文地质资料显示,青龙寺~延兴门区间暗挖段拱底埋深约37.5m,拱顶埋深约27.4m,此段地下水位位于地面下约12m,隧道洞身均已进入地下水位线以下,要达到无水作业的条件,降水深度需达到25m左右,隧道洞身地层范围内岩层主要为第四系中更新统老黄土及古土壤,均为含水层,无连续隔水层分布。在西安黄土地质条件下,基坑及隧道降水深度达25m,施工目前未有工程实例,由于降水深度比较大,暗挖施工降水难度大大提高,同时由于隧道顶部分布有层厚5.3~8.1m的饱和软黄土,饱和软黄土呈软塑~流塑状态,属高压缩性土,降水后的压缩沉降引起的地面沉降会造成地下管线、地面建筑物的破坏。青延暗挖区间采用以下措施控制水位:(1)由于暗挖段降水降深大,采用普通降水井无法达到降水效果,采用二级降水法分阶段进行降水施工,即采用双排降水井降水。第一阶段,采用外排降水井将地下水位降至地下25m以下,然后将地下水位维持在地面以下25m左右,待地面沉降稳定后再进行第二阶段降水;第二阶段,采用内排降水井降低地下水位,利用内排降水井保证洞内无承压水及大股明流水。在降水过程中加强对周边建筑物的监测,根据监测反馈信息的分析,当地面沉降过大达到报警值时应停止降水,采用洞内超前注浆方案。区间隧道施工前须做降水试验,将水位降至洞顶以下1m处,观察实际地面沉降量。如实际地面沉降量在允许范围内,则逐步降到洞底以下1m;如实际地面沉降量超过允许范围,则应停止降水,并及时采用井内回灌或采取洞内注浆止水,确保地面建(构)筑物安全和基坑无水作业。(2)WSS注浆。洞内引进WSS洞内深孔注浆技术,通过浆液扩散,将浆液充填地层土体空隙内,固结地层,隔离外来水体,达到止水帷幕的止水效果,将洞外井点降水与洞内WSS注浆相结合的方法,阻止了地下水侵入掌子面,保证干燥作业条件,确保了施工安全及工程质量。
3.2下穿地裂缝段施工
本标段青龙寺至延兴门区间暗挖段ZDK22+944.186(YDK26+943.076)有1条f7地裂缝与f7-1相交,走向NEE向,倾向南倾角约80度,由于地裂缝的存在,不适宜使用盾构法施工,采用浅埋暗挖法施工,由于盾构需通过地裂缝区间暗挖段,致使暗挖隧道施工断面加宽、加高,最大断面宽度10.1m,高度10.32m。如果降水达不到效果,易引起地下水通过地裂缝而涌入隧道,同时地裂缝段土体较破碎,开挖过程中易出现局部坍塌情况,施工安全风险较大。地裂缝施工时,由于掌子面积水及明流水较大,隧道开挖过程中采用洞内盲沟进行排水。掌子面三米处铺设φ609mm×16mm钢管,作为安全逃生通道。在开挖洞内两侧底部各设置一道300mm×300mm盲沟进行排水,盲沟采用碎石铺底。保证了掌子面积水及时通过盲沟排往竖井集水坑,避免掌子土体由于长时间受积水侵泡发生垮塌。开挖前采用WSS注浆控制掌子面土体稳固,遵循“先注浆,再开挖”的原则进行地裂缝段施工,确保了施工安全。
3.3复杂地质及带水作业沉降控制
由于青延暗挖段地质复杂,降水过程及开挖过程均极易造成地表及建筑物等出现沉降,因此施工过程中沉降控制也是一项重点及难点。青延区间暗挖隧道监测项目包含:地面下沉、建筑物倾斜、沉降、隧道拱顶下沉、净空收敛等。其中,地面沉降点共布设120个,累计沉降量最大点位位于前处理车间南侧草坪,沉降量-323.5mm;建筑物沉降点共布设65个,累计沉降量最大点位位于前处理车间西南角,沉降量-224.1mm;拱顶沉降点共布设102个,累计沉降量最大点位位于左线青龙寺方向洞口处,沉降量-55.1mm;净空收敛监测点共布设163个,累计变形量最大点位位于左线延兴门方向,变形量-51.7mm。隧道初支施工设计采用CRD法进行施工,CRD工法为每个导洞一次开挖成环,每个导洞高度达4.98-5.37m,由于开挖过程中地层有渗水情况且导洞开挖高度较大,不利于施工安全,施工过程中沉降难以保证,在实际施工时,在CRD工法增加连接板两处,增加锁脚锚管4处,将CRD上导洞分为上下两个导洞,单独进行开挖,单独支护,按照“快支护,早封闭”的原则,严格按照设计方案及步序进行施工,在施工完初期支护结构之后,必须及时施作内衬,严格控制初期支护与二次衬砌之间的安全距离控制了洞内及地面的沉降。
4结束语
总之,西安地铁三号线青龙寺~延兴门暗挖段在克服了埋深较大、地质复杂、降水难度大等困难后在保安全、保质量、保进度的情况下已于2014年10月顺利完工,施工中的一些施工亮点和做法也得到了业主、监理等上级单位及一些兄弟单位的认可,同时,西安地铁三号线在2016年10月顺利通车。
参考文献
[1]柏明虎.南京地铁二号线汉-上区间浅埋暗挖隧道施工技术[J].西部探矿工程,2015(05):195-197.
[2]赵旭.富水地段浅埋暗挖地铁隧道施工技术研究[J].建筑工程技术与设计,2016(96).
第五篇:地铁暗挖车站(区间)技术员考试题(带答案)
中铁**局**地铁1号线2013技术员专业考试(综合卷)
一、不定项选择题,共15题(15分,每题3分)
1、根据**站设计图,1、2号线主体衬砌所用的c30混凝土主要用在哪些部位()。
A钢管柱 B挖孔桩 C底纵梁 D 冠梁 E拱部 F基底回填
2、衬砌施工铺设的防水板,总会预留一定长度,这样既能保证下一步工序施工方便也保证了防水板有效搭接,那么图纸规定预留长度为()
A 20cm B 30cm C40cm D 50cm E 45cm F 35cm
3、在建筑所用钢材中按力学性能分为一二三级钢材,以下代表三级钢材的缩写正确的是()
A HPB235 B HRB335 C HRB400 D RRB400
4、图纸上经常出现的符号都有其一定的意义,如10C28@200中@代表(),数字10代表()
A 数量 B 间距 C 型号 D 尺寸
5、车站施工时标高控制是一件很重要的工作,一般车站控制标高是以某一个标高为基准根据结构尺寸推算出其他结构标高,那么基准标高取哪一点()A 底板顶面标高 B 轨底标高 C 轨面标高 D 站台板顶面标高
二、填空,共10题(30分,每题3分)。
1、浅埋暗挖施工的十八字方针是:管超前、严注浆、短开挖、强支护、快封闭、勤量测。
2、建筑施工冬期施工规程:当室外气温连续5 天低于5 度时即进入冬期施工。
3、衬砌施工时纵向受力钢筋机械连接接头和焊接连接接头位于同一截面数量不超过50%,且接头错来最小距离为35d且不小于500mm。
4、**站竖井、风道、主体初期支护所用的混凝土为:C20早强喷射混凝土。
5、本工程初期支护保护层厚度为内侧40mm外侧40mm。
6、钢格栅洞内安装,允许偏差为:横向±30mm ,纵向±50mm,高程±30mm,垂直度5%。
7、我们所使用的AutoCAD中为了方便使用通常会用到快捷键,那么画圆的快捷键是c ,移动的快捷键是m,复制的快捷键为co。
8、本工程设计图纸对衬砌钢筋的某些特殊位置长度都做了规定,对锚固长度规定,钢筋直径>25mm时锚固长度为大于钢筋直径34d(>=34d),钢筋直径<=25mm时锚固长度为大于钢筋直径的31d(>=31d)。楼板、柱、梁、墙、拱部所用的拉筋、开口箍筋弯钩直段长度为5d。
9、结构衬砌在两个结构体连接的位置为了减小因不均匀沉降造成的结构物破坏需设置一道或几道贯通的施工缝,根据你对图纸的理解或现场观察写出变形缝中需要设置的几个必须的部件钢边止水带、背贴止水带、变形缝衬板、聚硫密封胶(至少填三种)。
10、车站及区间防水板铺设时,结构防水图均对垫片间距做了相关规定,防水板垫片应梅花形布置,侧墙上固定间距为80~100cm,顶拱上固定间距为50~80cm,仰拱上的固定间距为1~1.5m,仰拱及侧墙连接部位固定间距应加密至50cm。所有垫片均应选择基层凹坑处固定,避免固定防水板时局部过紧。
三、解答题,共5题(40分)。
1、水准测量是现场施工技术人员必备技能之一,请解答什么叫后视点、后视读数?什么叫前视点、前视读数?高差的正负号是怎样确定的?
答:后视点:标高测量时以测量方向为标准先读取后方的点为后视点;后视读数:后视点上标尺在水准仪中读取的数值;
高差的正负号是怎样确定的:从起点到终点,标高抬高即为正值反则为负值。
2、请简述本工程施工中预留核心土、微台阶法施工重要性。
答:为了掌子面的稳定,防止塌方所采取的措施之一;
3、现浇结构工程浇筑前应完成那几种工作:(写出三条即可满分)
答:
1、隐蔽工程的验收和技术复核(模板复核、钢筋数量尺寸验收);
2、对操作人员(浇筑工人)技术交底;
3、检查施工现场是否具备施工条件(检查照明、振捣设备、管线等);
4、填写浇筑申请单向监理工程师报验。
4、地铁暗挖隧道人工开挖时要求对每一榀格栅都要严格控制,项目部也对现场技术人员进行了多次教育和交底,请你写出暗挖隧道一榀格栅从开挖到支护完成所有控制要点。(写出8条即可满分)
答:
1、开挖进尺,2、台阶长度,3、核心土留置情况,4、超欠挖,5、格栅里程(标高)同步,6、格栅垂直度(水平),7、连接筋、8、加强筋数量及焊接质量,9、螺栓数量以及是否拧紧,10、连接板是否有开口,11、网片是否为内外层并搭接20cm(或1个网格)网片是否绑扎,12、格栅定位(不侵入净空),13、喷锚面平整度,14拱顶或背后是否有孔洞、空洞,15加密筋数量(竖井),16断面变化情况及交底(区间),17、格栅是否合格。
5、请写出施工资料包括的八个主要内容。
答:(1)工程管理与验收资料;(2)施工管理资料;(3)施工技术资料;(4)施工测量记录;(5)施工物资资料;(6)施工记录;(7)施工试验记录;(8)施工质量验收记录。
四、畅谈题