第一篇:抄表器程序培训文档
目录
一.TP1100与PC连接操作........................................................................................................2 二.TP1100外观说明...................................................................................................................2 三.TP1100键盘操作指南...........................................................................................................4 四.TP1100程序功能说明...............................................................................................................6 1.抄表主菜单...................................................................................................................................6 2.抄表.............................................................................................................................................7
1)按“上”键.....................................................................................................................7 2)按“下”键.....................................................................................................................7 3)按“左”键.....................................................................................................................7 4)按“右”键.....................................................................................................................7 5)按“.”键....................................................................................................................7 6)按“ 1”键:.................................................................................................................8 7)按“ 2”键:.................................................................................................................8 8)按“ 3”键:.................................................................................................................8 9)按“ 4”键:.................................................................................................................9 10)按“6”键:.................................................................................................................9 11)按“换挡”+“4”键:.................................................................................................9 12)按“功能”键:...........................................................................................................9 13)按“确认”键:.........................................................................................................10 a.当电能表为中小用户“机械表”..............................................................................10 b.当电能表为中小用户“复费率电表”......................................................................10 c.当电能表为大用户“多费率电能表”.........................................................................12
3.抄表图.......................................................................................................................................13 4.查询...........................................................................................................................................14 5.帮助...........................................................................................................................................17 四.TP1100保养与维护..............................................................................................................19 一.TP1100与PC连接操作
首先,要安装USB驱动程序。
第二,要在通讯设置界面选择“USB”通讯。第三,选择“进入通讯状态”。
最后,微机运行营销系统上下装数据。
二.TP1100外观说明
红外口和激光头; 2 指示灯; 3 液晶显示屏 ; 4 复位键 ; 5 一体式防滑手柄;6 键盘 ; 7 挂绳钩 ; 8 蜂鸣器 喇叭 ; 10 主电池仓; 11 电池锁扣 ; 12 背带固定1 ; 13 充电口 ; 14 通讯口; 15 背带固定2
三.TP1100键盘操作指南 “开关”键
用于启动或结束TP1100数据采集终端的运行。当机器处于关机状态时,按下“开关”键机器将被打开;当机器处于开机状态时,按下“开关”键机器将被关闭。2 “换档”键
单独按“换档”键是无意义的,“换档”键必须和除“开关”键以外的另外的键组合才起作用。组合办法是按下“换档”键的同时按下欲组合的键。3 复位键
复位是一个比较危险的操作,一般应禁止。只有当系统发生异常,无法正常操作时,才建议使用,复位后机器将重新上电初始化。其操作只需触击复位孔内的小按钮即可。4 控制键
控制键除了实现相应的控制功能以外,还可以和“换档”键组合使用,下述是其中较为通用的控制作用。
【复位】键:使机器重新回到开机状态。【电源】键:开机/关机。
【换档】键:功能组合键,和其他键组合实现一定的操作功能。
【换档】+【功能】:在主界面下,实现字符界面和图形界面的相互切换。【换档】+【退出】:退出ZZdbase语言编写的用户程序 【确认】键:确认某项操作。
【退出】键:返回上一级目录/取消当前操作。
【导航】键:包括上、下、左、右四个方向,滚动浏览菜单和列表以及切换、设置可选项。
【删除】键:删除光标前的信息。【功能】键:在拼音输入状态下,切换双拼输入/预留键位,供用户开发自定义。
【切换】键:切换输入法及输入状态。【扫描】键:激光头扫描时使用。
【软键】:图形界面及DBASE程序运行界面下可方便快捷完成退出、确认、功能的操作。5 字母数字键
这几个按键均位于键盘的下半部,当单独按下这些键时,则会输入相应的数字或小数点;在软件允许的情况下,可输入对应的符号或字母。由于每个键上有四个数字、符号或字母,当要输入某一键上的第几个字符时,在相应的按键上连续按几下即可。用户程序可以禁止输入运算符和字母,一律都只输入数字。四.TP1100程序功能说明
1.抄表主菜单
(1)10行12列界面方案
抄表信息界面第1页
备注:此功能起提示作用,方便查看掌机时间是否正确,以便在抄表过程中实现准确的校时。
按确认键显示第2页
备注:显示抄表程序的主菜单 2.抄表
选择“1.抄表”选项后进入如下界面:
上图显示用户信息:册序,表号,户号,户名,地址,表计类型,已抄息等等。
在上图界面可实现一下功能:
1)按“上”键:实现向上浏览用户信息。2)按“下”键:实现向下浏览用户信息。3)按“左”键:实现向前查找未抄用户。4)按“右”键:实现向后查找未抄用户。5)按“.”键:设置电表异常。如图
/未抄信6)按“ 1”键:查看完整户名地址。如图
7)按“ 2”键:
8)按“ 3”键:
查看电表状态信息。如图
查看抄表状况。如图 9)按“ 4”键:返回抄表记录的第一条。10)按“6”键:返回抄表记录的最后一条。11)按“换挡”+“4”键:调出抄表信息图
如图
12)按“功能”键:弹出扩展菜单
如图
一共12个选项:查看帮助,置异常表,抄表图,统册查询,表号查询,户名地址,状态信息,抄表信息,微电出账,前一未抄,后一位超,下一异常等功能。
13)按“确认”键:实现电能表数据抄收。
a.当电能表为中小用户“机械表”时,按下“确认”键程序自动转入手工抄收。抄表员根据现场电表示数录入即可完成抄表。(如下图)
当抄表员录入本月示数后,自动转入电量计算模块,并根据mrdate.dbf中ALARM_FLU字段(注:抄表预警波动值)内容提示电量过大或者过小。
b.当电能表为中小用户“复费率电表”时,按下“确认”键程序自动转入中小用户红外抄收模块,完成对电表的数据抄收和时间校对。
当抄收过程中没有任何提示,直接显示如下界面代表校时成功,电量抄收成功。此时抄表员根据电表实际示数与掌机抄收示数选择内外存是否一致。(注:抄收冻结电量时掌机抄收示数跟电表实际示数不符。)
当抄收过程中,时钟抄收失败,时钟对时失败会有相应的错误提示。(抄收电表时钟失败提示:读取电表时钟失败。电表时钟校时失败提示:电表校时失败。)同时抄表机中此户异常标识为:“时钟异常”。如果电量抄收失败会有“重抄,放弃,手工”异常提示菜单。抄表员可以根据现场实际情况进行选择。
当抄收过程中,没有提示电表时钟读取失败,时钟对时失败的提示信息。而是提示“重抄,放弃,手工”的异常菜单,代表校时成功,而电量抄收没有成功,此时抄表员可以根据现场实际情况进行选择。
c.当电能表为大用户“多费率电能表”时,按下“确认”键键程序自动转入大用户红外抄收模块,并根据mrdate.dbf中COMM_PROT字段自动识别电表红外通讯规约,完成对电表的数据抄收和时间校对。
注明:在校时上按照“大中小量用户一体化抄表掌机技术规范.doc”中要求。
对于中小用户“复费率表”校时采取:掌机与电表时钟偏差15分钟以上不校时,用户信息标注“时钟异常”;掌机与电表时钟偏差15分钟以内且大于3分钟校时,成功无异常信息,失败标注“时钟异常”;掌机与电表时钟偏差3分钟以内,不需校时,用户信息无异常。
对于中小用户“智能表”校时采取:掌机与电表时钟偏差5分钟以上不校时,用户信息标注“时钟异常”;掌机与电表时钟偏差5分钟以内校时,成功无异常信息,失败标注“时钟异常”。对于大用户“多费率电能表”校时采取:掌机与电表时钟偏差15分钟以上不校时,用户信息标注“时钟异常”;掌机与电表时钟偏差15分钟以内3分钟以上校时,成功无异常信息,失败用户信息标注“时钟异常”;掌机与电表时钟偏差3分钟以内不校时,用户信息无异常。
对于大用户“智能表”校时采取:掌机与电表时钟偏差5分钟以上不校时,用户信息标注“时钟异常”;掌机与电表时钟偏差5分钟以内校时,成功无异常信息,失败标注“时钟异常”。
3.抄表图
选择主菜单第二项“抄表图”后显示如图
抄表图是以图形符号的方式显示用户表信息,界面直观,操作方便。其中:
“.” : 未 抄 “o” : 已 抄 “x” : 异 常 4.查询
选择主菜单第四项“查询”显示菜单如下:
1)选择“统册号查询”
抄表员可以根据下图了解掌机内抄表册号及对应的用户数量。
2)选择“表号查询”
抄表员可以通过输入抄表现场的“电表号”来完成对电表信息的快速查找。注:可以实现模糊查询。输入电表表号时,可以输入表号后面的任意几位。(一般建议输入4位以上能准确快速定位。)
3)选择“户号查询”
抄表员可以通过输入 “用户号”来完成对电表信息的快速查找。注:可以实现模糊查询。输入用户号时,可以输入户号后面的任意几位。(一般建议输入4位以上能准确快速定位。)
4)选择“抄表图查询”
抄表员可以通过“抄表图”快速定位未抄用户实现快速查找功能。
5)选择“记录号查询”
抄表员可以根据输入记录自然号来快速查找用户信息。
注:记录号,一般为营销mis下装mrdate.dbf文件中用户的自然顺序。
6)选择“非红外查询”
会定位到记录中第一个应该用红外抄收而用其他方式抄收的用户。并通过上下键可以查找浏览所有非红外抄收用户。5.帮助
选择主菜单第五项“帮助”后显示如下: 抄表员可以根据菜单内容选择需要了解的功能。
1)选择“抄表”
抄表帮助第一页介绍界面信息,及抄收和功能按键。
抄表帮助第二页介绍界面信息中个功能的快捷按键。
抄表帮助第三页介绍界面信息中个功能的快捷按键。
2)选择“抄表图”
抄表图帮助第一页介绍抄表图中图形代表的含义。
抄表图帮助第二页介绍抄表图中各个按键的作用。
五.TP1100保养与维护
注意事项
使用抄表机时,由于种种原因不慎将其掉入水中,从水中取出后,请您将其风干,切忌,不要开启开关,以免电池漏液毁坏机内电路板。
抄表机的屏幕外面,覆有一层塑料保护薄膜,请您在使用前,最好不要将其取下,以防屏幕磨损。
如果没有妥善的屏蔽设计,或未充分进行电磁容性配置,几乎所有的电子设备都易受到电磁干扰;请您在贴有通知的场所关闭机器并尽量避免在强光下使用,可能这些场所正在使用外部射频信号敏感的设备。
特别说明:如果配电室中有日光灯,并且出现抄表反复失败的时候,可能是日光灯干扰,可以尝试关掉日光灯进行抄表。
电池的使用
数据采集终端所使用的是锂电池。
当电池电量不足时,会出现警告信息,但允许数据采集终端继续工作。用户应尽快充电。否则,当电池耗到不能继续供电时,数据采集终端就会停止工作,屏幕上无任何显示,也不可能开机。
充电
可充电电池是有使用寿命的。在使用恰当的情况下,充放电300 次以后,容量一般将降到80%以下。如果使用不当,寿命会更短。
第二篇:抄表安全知识培训
抄表员安全知识培训
为了确保抄表员安全工作落实到位,确保抄表过程中抄表员自身安全和行人安全,现对抄表人员进行安全知识培训:
一、抄表员在抄表途中,注意行走和行车安全;
二、抄读水表时,在开启水表表箱前要注意周围情况,表位在厂门口、巷口等要道的要注意来往车辆和行人,在建房修房工地抄表要注意上空坠物和地下尖利物。对围观的群众,特别是围观的小孩要耐心劝其离开,以保证抄表工作的安全,开启表箱时要集中精力,两腿分开站在表箱框外,对大的小水泥箱可采用“移动法”慢慢开启,对铁箱盖应注意插销是否完好,箱盖开启的角度必须大于90度,防止箱盖失去平衡翻倒压伤手脚。冰冻天橇表箱盖要防止碰伤,不要用力过猛,以防铁钩打滑、断裂。在掏挖水表时要先摸清表位周围的情况,防止损坏地下供电电缆,电话电缆等市政设施,避免触电事故。
三、水表抄读完毕后要将表箱盖放平盖好,对已损坏的影响操作、影响安全的表箱盖要及时上报。
第三篇:抄表作业指导书
篇一:营业抄表作业指导书 营业抄表作业指导书
一、抄表作业流程
二、抄表前的准备工作
1、抄表器管理
抄表器管理包括抄表器的购入、出库、入库、返修、报废、分配给抄表员和分配给部门等操作。工,将故障的抄表器进行返修或报废处理。
2、抄表区段管理
抄表区段管理包括区段的增加、删除、修改和重新调整以及抄表序号的调整和打印抄表通知单等操作。
抄表区段管理需注意对新装用户进行区段编号;对用户调整区段时要注意台区的划分是否正确。抄表员可根据合理的抄表路线,调整各区段的抄表序号。
3、抄表计划管理
抄表计划管理包括抄表计划的生成、调整、终止、恢复、归档和解锁,以及统计抄表计划执行情况等操作。
抄表计划的状态包括: 初始化:抄表计划生成后。发送:抄表计划下装后。
形成数据:初始化和发送之间的状态。接收:抄表计划上装后。
计算:抄表计划对应的区段计算完电量电费后。
锁定:对计算正确的区段对应的抄表计划进行加锁后。发行:对锁定的抄表计划对应的区段进行发行后。终止:对抄表计划进行终止操作后。
在抄表计划管理中需要强调的是:只有生成抄表计划后才可进行抄表工作;发行完的抄表计划一定要做归档操作,否则下个周期无法制定抄表计划;对处于发送、形成数据、接收、计算和锁定状态的抄表器和卡表抄片抄表用户的抄表计划不可进行终止操作。
4、了解个人抄表例日、工作量及地区收费例日与抄表例日的关系。
5、掌握抄表器的正确使用方法。
4、按例日领取下装后的抄表器、抄表通知单及欠费催费通知单,复核抄表器质量和下装内容。
5、备齐抄表有关用具,如工具包、抄表器(电源充足)、手电筒、钢笔、抄表通知单、催费通知单等。
6、出现场前应佩证(工作证或服务标志牌)。
四、现场抄表
1、根据抄表例日,按抄表顺序实际到达每个下装用户的表计装设处。
2、进行每户抄表时,根据抄表器内信息现场核对电表号码、ct倍率、检查表计封印及运转情况,表计有无烧损、毁坏现象,有无违章、窃电行为,峰谷分时表时钟显示是否准确等,对新装用户还应认真核对户号、户名、用电类别、电压等级、设备容量、电表厂家、型号、容量、ct号码、倍率,对大用户的抄表应检查pt二次接线是否正常,熔丝加封是否正常,有无熔断,对有备用电源的用户,无论用电与否都应进行抄表。
3、将抄读的有、无功实际表示数现场录入抄表器,并发放电费通知单和欠费催费通知单。
4、发现电量突增、突减时,应及时查明原因。
5、发现户名、地址、表型、表号、表位、倍率、容量等与现场不符时,应在抄表器内注明。
6、发现电表故障,应先按表计示数抄记,并在抄表器的指令栏内注明。
7、有下装户而现场无表的应在抄表器的异常栏内记录。
8、发现用户有违章窃电行为时要填制违章窃电通知书,并请用户签字,“通知联”交给用户,“存根联”回局交用电检查处理。
9、因用户原因需要进行估算时,必须在抄表器的指令栏内注明,但同一户估算不能连续超过两次,区域内漏抄户必须及时补抄。
10、负控抄表和集抄抄表时,要先按例日做好数据的召抄工作。
11、抄表区段上装后,按区段打印《抄表回传数据统计表》。
五、异常检查及处理
1、抄表员对接收数据进行检查,如发现需要修改的电量,则抄收工填写《修改示数申请表》,并经抄收班长签字后转给营业班长。
2、发行人员对上装的抄表示数进行核对,对复核出的异常电量要填写《电量异常信息提交表》,并转交抄收工进行落实。
3、复核内容
? 峰平谷电量之和大于总电量的。? 峰谷电量之和大于总电量的。? 本月示数小于上月示数的。
? 零电量、电表循环、未抄、有协议电量或修改过示数的。? 抄表自动带回的异常:反转、估抄等。
? 与同期或历史数据比较进行查看:指定n个月(一般用前三个月的)平均电量做比较,核对电量突增突减的用户。
? 按电量范围进行查看:指定电量范围,查看用户数据是否正确。? 连续3个月估抄或连续3个月划零的。
? 档案变更:档案变更(包括新装)归档后第一个周期抄表的。
4、接到《电量异常信息提交表》后,抄收工要到现场对异常电量进行核实。
5、如电量正确则抄收工签字并转回发行人员,可以进行计算发行。
6、如电量错误则抄收工填写《修改示数申请表》,并经抄收班长签字后转给营业班长。
7、营业班长根据《电量异常信息提交表》和《修改示数申请表》更正错误电量。
8、上装时通过系统提交的异常情况,用电检查人员要根据异常类型打印工作任务书,安排人员到现场检查,并依据现场检查结果进行相关处理。
六、资料保管
按月将下列资料装订保管,以备查询
1、《抄表回传数据统计表》
2、《电量异常信息提交表》
3、《修改示数申请表》
七、主要功能模块
1、综合查询—档案查询、欠费查询、交费查询
2、数据采集
3、应收管理—电量电费查询 附件1:《电量异常信息提交表》 附件2:《修改示数申请表》 附件3:《抄表流程操作说明》篇二:抄表作业指导书1.0目的
便于能源成本核算、更好的进行能源分析、测算及做好节能降耗工作。2.0范围
适用于亚运新新家园水、电、气的抄表计量作业。3.0方法及过程控制
3.1本园区的抄表计量包括:电气抄表计量、自来水抄表计量、生活热水抄计量、管道天燃气抄表计量,工程部应分系统建立抄表计量档案。
3.2.1电气计量档案包括:供电局收取电费收据的复印件、每月园区用电量总额、各类电费单价、各类用电明细、各区域用电明细等。电气计量由电气领班负责。3.2.2自来水抄表计量档案包括:自来水公司收取水费收据的复印件、每月园区用水量总额、各类水费单价、各类用水明细、各区域用水明细等。自来水计量由水暖工程师/领班负责收集。3.2.3生活热水抄表计量档案包括:生活热水单价、生活热水用水总量、业主用水总量、各户用水量、其它用水量等。生活热水抄表计量工作由水暖工程师/领班负责。
3.2.4燃气抄表计量档案包括:燃气公司收取气费收据的复印件、每月园区用气总量、各类气费单价、各台锅炉用气量明细等。燃气抄表计量工作由水暖工程师/领班负责。
3.2各系统抄表计量负责人每月20日对各系统计量表进行抄表,记录在《抄表记录表》中,并核算出各类能源消耗量,汇总为各系统月份《能源汇总分析表》并对其进行分析,报工程部经理审核。各系统抄表计量负责人每月25日前做出下月各能源消消耗量预测,并报工程部经理审核。
3.3工程部每月5日把上月各系统《能源汇总分析表》、收据复印件(原件存在综合部)整理成上月各系统计量档案,由工程部经理审核完报项目管理处总经理指示后存档。
3.4每年12月25日前,各系统抄表计量负责人统计汇总出各系统《抄表计量数据统计报表》并进行分析,报工程部经理审核。4.0质量记录和表格 《抄表记录》
《能源汇总分析表》篇三:微功率无线集中抄表系统作业指导书(2010-11-26)微功率无线集中抄表系统 作业指导书
版本号:2010-11-26目 录 第 1 章
1.1 1.2 1.3 1.4 第 2 章 2.1 2.2 2.3 2.4 2.5 第 3 章 3.1 3.2 3.3 第 4 章
4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 第 5 章 第 6 章 无线抄表系统结构说明..................................................................................................................3 主站..................................................................................................................................................3 通信信道..........................................................................................................................................3 采集终端..........................................................................................................................................3 现场表计..........................................................................................................................................4 微功率无线通讯介绍......................................................................................................................5 技术参数..........................................................................................................................................5 技术特点..........................................................................................................................................5 不同通讯方式的比较......................................................................................................................5 影响无线通信距离的因素..............................................................................................................6 提高通信距离的措施......................................................................................................................8 电表模块的外观和安装..................................................................................................................9 外观..................................................................................................................................................9 单相远程费控电表模块的安装....................................................................................................10 模块指示灯状态............................................................................................................................10 集中器的安装.................................................................................................................................11 集中器的结构.................................................................................................................................11 sim卡的安装.................................................................................................................................12 天线的安装....................................................................................................................................12 集中器的安装地点选择................................................................................................................13 安装准备........................................................................................................................................14 集中器的安装................................................................................................................................15 集中器电源接线说明....................................................................................................................16 填写集中器安装工作单................................................................................................................16 集中器状态显示............................................................................................................................17 集中器的液晶显示....................................................................................................................18 集中器的调试步骤........................................................................................................................22 现场故障排查与处理....................................................................................................................24第 1 章无线抄表系统结构说明 一个典型的无线自组网的自动集抄系统包括集中器、智能电表、gprs上行信道及后台系统(营销系统、采集系统、售电系统)等,如下图所示: 1.1 主站
主站是对电力用户的用电信息进行采集、处理和实时监控的系统,实现用电信息的自动采集、计量异常监测、电能质量监测、用电分析和管理等综合应用。1.2 通信信道
通信信道实现集中器到主站的数据传输,信道可选用光纤专网、gsm/gprs/cdma无线公网、230m专网等不同的通信信道进行数据传输,具体采用某种通信信道需要因地制宜,根据用户的环境特性选择合适的信道,系统支持采用多种信道来完成系统的数据通信。1.3 采集终端
现场采集终端,在本系统中主要是低压集中抄表终端,负责电能信息的采集、数据管理、数据传输以及执行或转发主站下发的控制命令。? 低压集中器
低压集中器集中管理一个区域内的电能表数据采集、数据处理和通信管理,它可与低压采集器或具有通信模块的电能表交换数据。
集中器是集抄系统的核心部分,主要负责通过宽带或窄带载波方式、rs485方式、微功率无线方式直接抄收电表数据或者通过采集器转发采集电表数据,通过gprs/cdma、电话modem、有线等方式将数据传输给智能抄表管理系统主站,实现远程自动抄表。1.4 现场表计
现场表计位于电力用户端,根据不同的用户性质安装不同类型的电能表,最新符合国家电网智能电表标准的电表可以灵活更换为载波通信模块或微功率无线通信模块,通过和集中抄表终端同样通信模块的配合,可以实现对现场表计的数据采集组网。
第 2 章 微功率无线通讯介绍 2.1 技术参数
工作频率:470mhz ~ 510mhz调制方式:gfsk 发射功率:17dbm工作电压: dc 5v±5%/dc+12v~+15v 无线速率:9600bps 接口速率:9600bps 信道带宽:200khz 静态电流: ≤30ma 天 线: 阻抗50ω, 接头sma 2.2 技术特点
网状网络 :超稳定的网状网络构形,节点拥有多至20个邻居数,并具有瞬间自我路由修复功能,适应各种复杂、多变的现场环境;
自动组网 :新装无线智能电表、无线采集器(无线节点)由集中器智能组网,无需对现场设备进行设置;
多跳路由:免现场设置、全智能自动路由、中继,中继级数可达20级,无需额外增加任何中继,单网最大支持1024节点;
跳频技术:随机多信道跳频通信,解决单频工作(同一子网)时,社区范围使用同一频带的不同厂家、不同类型无线设备间的互扰,通信可靠性高。2.3 不同通讯方式的比较
篇四:电能表现场检验作业指导书 电能表现场检验作业指导书 1 适用范围
本作业指导书适用于电能表的现场首检、周期检验和用户申验。2 检验依据
国家电网公司电力安全工作规程(国家电网安监[2009]664号)
关于印发《低压电能表装拆安全措施(试行)》的通知(营计〔2011〕57号)电能计量装置技术管理规程 dl/t 448-2000 关于规范用户申验业务电能表现场检验工作的通知(闽电营销(2009)884号)3 检验条件 3.1 环境温度:(0~35)℃ 相对湿度:≤85% 3.2 现场检验时,当负荷电流低于被检电能表标定电流的10%或功率因数低于0.5时,除误差检验不宜开展外,其它检验项目,如电能表接线正确性、电能表功能检查等仍应开展。3.3 负荷相对稳定。4 安全工作要求
4.1 填用工作票(含低压工作任务单等),并严格遵守《国家电网公司电力安全工作规程》相关规定。
4.2 参照《低压电能表装拆安全措施(试行)》要求做好安全措施。4.3 至少有两人一起工作,其中一人进行监护。4.4 配置并正确使用合格的安全工器具。
4.5 测试仪和试验端子之间的连接导线应有良好的绝缘,中间不允许有接头。4.6 在接通和断开电流端子时,必须用仪表进行监控。
4.7 电压互感器二次回路严禁短路,电流互感器二次回路严禁开路。4.8 现场检验应使用具有漏电及过流保护功能的电源插座。5 检验设备
5.1 0.05级及以上三相电能表现场测试仪(以下简称测试仪); 5.2 0.2级及以上单相电能表现场测试仪(以下简称测试仪)5.3 数字万用表; 5.4 相序相位表。6 工作程序 -3-6.1 首检
6.1.1 办理第二种工作票(或工作任务单)。
6.1.2 注意工作区域与带电设备应保持足够的安全距离。防止误碰开关等操作设备。6.1.3 检查电能表、失压仪等设备是否完好无损。外观整洁无裂痕,标志清晰,螺 丝、接线等接触良好。
6.1.4 检查被检电能表接线是否正确,推荐用双钳相位伏安表,六角图法检查。6.1.5 具备辅助电源的测试仪,先打开电源开关通电预热。
6.1.6 按极性、相别标志将测试仪测试导线接入电压、电流回路。
6.1.7 用万用表检查测试仪的电压、电流回路,电流二次回路不应开路,电压二次 回路不应短路。
6.1.8 根据现场电能表的电压、最大电流(最大值)规格,手动选择测试仪合适的 电压、电流量程,接线方式,设置电表脉冲常数,选择误差测量功能。
6.1.9 打开试验接线盒罩壳,先串联接入测试仪电流回路,再并联接入电压回路,确认接线正确、牢固可靠。
6.1.10 逐相缓慢打开接线盒电流回路的短路片,同时监视测试仪的电流指示,确认 电流回路未开路后,再完全打开短路片,记录电压、电流值。
6.1.11 待电压、电流值稳定后,再次手动选择合适的电压、电流量程或切换回自动 量程模式,采用光电或脉冲取样方式进行现场检验。
6.1.12 在测试仪达到热稳定后,且在负荷相对稳定的状态下,测量误差。测量次数
一般不得少于2次,取其平均值作为测量结果。当测量结果在最大允许值的80%~120%时,至少应再增加2次测量,取多次测量数据的平均值作为测量结果。测量结果不应超过被检表等级指标。6.1.13 恢复接线盒电流回路的短路片,并确认短接可靠。
6.1.14 先拆除电压回路,再拆除电流回路接线,恢复试验接线盒罩壳。6.1.15 拆下脉冲线,检查被检电能表的显示是否正常。6.1.16 关闭测试仪电源。
6.1.17 电能表功能检查(适用于多功能表)(1)检查电能表的显示、按钮是否正常。
(2)电能表内部时钟检查。检查被检电能表内的日历时钟,日历应与当前日期 一致,时间与北京时间相差应小于等于3min。
(3)电池检查。检查电能表是否存时钟电池欠压、停电抄表电池欠压指示。
(4)失压记录检查。检查多功能电能表事件记录寄存器,并记录所计的失压次-4-数和起止时间。
(5)检查电能表是否存在故障报警。(6)检查费率时段设置是否正确。
(7)检查最大需量寄存器的需量周期、滑差间隔是否正确。(8)检查多功能电能表的结算日是否正确。(9)记录最后编程日期。
6.1.18 在工作单上记录检验结果,电能表、失压仪显示数据。6.1.19 清理工作现场,施加铅封并经用户代表签字确认。6.1.20 撤离工作现场后,办理工作终结手续。6.2 周期检验
6.2.1 办理第二种工作票(或工作任务单)。
6.2.2 注意工作区域与带电设备应保持足够的安全距离。防止误碰开关等操作设备。
6.2.3 检查电能计量装置(包括计量柜、电能表、试验接线盒、失压仪及二次回路等)的铅封情况,经在场人员确认完好无损后做好记录。
6.2.4 检查电能表、失压仪等设备是否完好无损。外观整洁无裂痕,标志清晰,螺丝、接线等接触良好。
6.2.5 检查被检电能表接线是否正确,推荐用双钳相位伏安表,六角图法检查。6.2.6 具备辅助电源的测试仪,先打开电源开关通电预热。
6.2.7 按极性、相别标志将测试仪测试导线接入电压、电流回路。
6.2.8 用万用表检查测试仪的电压、电流回路,电流二次回路不应开路,电压二次回路不应短路。
6.2.9 根据现场电能表的电压、最大电流(最大值)规格,手动选择测试仪合适的电压、电流量程,接线方式,设置电表脉冲常数,选择误差测量功能。
6.2.10 打开试验接线盒罩壳,先串联接入测试仪电流回路,再并联接入电压回路,确认接线正确、牢固可靠。
6.2.11 逐相缓慢打开接线盒电流回路的短路片,同时监视测试仪的电流指示,确认电流回路未开路后,再完全打开短路片,记录电压、电流值。6.2.12 待电压、电流值稳定后,再次手动选择合适的电压、电流量程或切换回自动量程模式,采用光电或脉冲取样方式进行现场检验。
6.2.13 在测试仪达到热稳定后,且在负荷相对稳定的状态下,测量误差。测量次数一般不得少于2次,取其平均值作为测量结果。当测量结果在最大允许值的80%~120%时,至少应再增加2次测量,取多次测量数据的平均值作为测量结果。测量结果不应 -5-超过被检表等级指标。
6.2.14 恢复接线盒电流回路的短路片,并确认短接可靠。6.2.15 先拆除电压回路,再拆除电流回路接线,恢复试验接线盒罩壳。6.2.16 拆下脉冲线,检查被检电能表的显示是否正常。6.2.17 关闭测试仪电源。
6.2.18 电能表功能检查(适用于多功能表)(1)检查电能表的显示、按钮是否正常。
(2)电能表内部时钟检查。检查被检电能表内的日历时钟,日历应与当前日期 一致,时间与北京时间相差应小于等于3min。
(3)电池检查。检查电能表是否存时钟电池欠压、停电抄表电池欠压指示。(4)检查电能表是否存在故障报警。6.2.19 必要时,对以下项目进行检查:
(1)失压记录检查。检查多功能电能表事件记录寄存器,并记录所计的失压次 数和起止时间。
(2)检查费率时段设置是否正确。
(3)检查最大需量寄存器的需量周期、滑差间隔是否正确。(4)检查多功能电能表的结算(冻结时间)日是否正确。(5)检查并记录最后编程日期。
6.2.20 在工作单上记录检验结果,电能表、失压仪显示数据。6.2.21 清理工作现场,施加铅封并经用户代表签字确认。6.2.22 撤离工作现场后,办理工作终结手续。6.3 用户申验
6.3.1 与用户约定现场检验时间,通知用户到场。
6.3.2 办理低压工作任务单及打印“电能表现场检验记录单”。
6.3.3 注意工作区域与带电设备应保持足够的安全距离。防止误碰开关等操作设备。
6.3.4 开展检验前,应对“电能表现场检验记录单” 中系统打印的电表参数等信息进行现场核对,如与现场不一致,应记录现场实际信息。并请用户对现场电能表型号、资产编码、底度等信息进行确认。
6.3.5 检查电能计量装置(包括计量柜、箱、电能表、铅封等)的情况,经在场用户确认完好无损后做好记录开始检验(被检电能表必须具有完整、完好的铅封方可检验)。6.3.6 单相电能表检验步骤
-6-(1)选择量程与当前电能表负荷相匹配的电流钳,不能确定当前负荷大小的应 先使用最大的量程进行试验。
(2)进行单相电能表现场校验时,现场测试仪电压取样点和电源应接到电能表 的进线端,电流钳应取至电能表相线的负载端(出线端)。以防止由于电能表的功耗和测试仪的功耗影响校验正确性。
(3)打开电能表接线盒罩壳,将测试仪的电压测试导线接至被检单相电能表相 线进线端,电流钳表接入被检单相电能表相线负载端,确认接线正确、牢固可靠。(4)打开测试仪电源开关,选择电流量程,设置电表脉冲常数,选择误差测量 功能。
(5)采用光电或脉冲取样方式进行现场检验。(6)记录电压、电流值和检验误差值。
(7)在测试仪达到热稳定后,且在负荷相对稳定的状态下,测量误差。测量次 数一般不得少于2次,取其平均值作为测量结果。当测量结果在最大允许值的80%~120%时,至少应再增加2次测量,取多次测量数据的平均值作为测量结果。测量结果不应超过被检表等级指标。在“电能表现场检验记录单”上记录检验结果等数据。(8)拆除试验接线,恢复电能表接线盒罩壳。(9)关闭测试仪电源。6.3.7 三相电能表检验步骤
(1)检查被检电能表接线是否正确,推荐用双钳相位伏安表,六角图法检查。(2)具备辅助电源的测试仪,先打开电源开关通电预热。
(3)按极性、相别标志将测试仪测试导线接入电压、电流回路。
(4)用万用表检查测试仪的电压、电流回路,电流二次回路不应开路,电压二 次回路不应短路。
(5)根据现场电能表的电压、最大电流(最大值)规格,手动选择测试仪合适 的电压、电流量程,接线方式,设置电表脉冲常数,选择误差测量功能。
(6)打开试验接线盒罩壳,先串联接入测试仪电流回路,再并联接入电压回路,确认接线正确、牢固可靠。
(7)逐相缓慢打开接线盒电流回路的短路片,同时监视测试仪的电流指示,确 认电流回路未开路后,再完全打开短路片,记录电压、电流值。
(8)待电压、电流值稳定后,再次手动选择合适的电压、电流量程或切换回自 -7-
第四篇:抄表员范文
“这幢楼,那幢楼,还有这两条街上总的2000多户,都是我负责抄收。”肩扛梯子,手拿抄表仪的许丽芳气喘吁吁地告诉笔者。
在云南省陆良县城区供电所,向许丽芳这样每个月要定期扛着梯子走街串巷去抄表的共有14名女子。陆良供电有限公司客户服务中心负责人说:“她们基本都是从其他部门竞聘来的,有的过去是变电站运行工,有的曾在电厂上过班,抄表是个苦差事,过去以为他们难以胜任,但几个月下来,每项工作都不比男员工差。”
好几个抄表员都哭了
今年8月份,14名从没有干过抄¬表工作的女职工走上了这个让很多男职工都怕干的岗位。以前新抄¬表员至少要熟悉收费系统两个月,再上岗实习三个月后才可以独立开展工作,可这一次她们却只有一个月的学习适应时间。
一进入工作,每个抄¬表员都有2200户左右的抄¬表量,公司为了加强线损管理和计算,要求全部抄表任务在六天内完成,同时出于安全等各方面因素的考虑,抄表工作要求两个人搭档完成。这就意味着6天内必须完成4400户左右的抄表量,算下来每天都得抄¬至少740户以上才能在规定时限内完成工作。这对于对抄表片区里的电表位置没有多少概念的人来说,是个不小的考验。在抄表的过程中,她们每天携带的随身物品有七、八公斤重的铝合金梯、工具包里装有记录本、抄表仪、修理工具、表箱钥匙等,全部有十几公斤之重。
每次抄表,上楼下楼不知要跑多少趟,特别是像龙海花园,十几层高的楼,就是空着手上下一次都相当耗费体力,更何况还有随身携带的物品。到农村抄表的,每次出门还得备足一天的干粮,而且晴天一身灰,雨天一身泥,对于爱美的女同志而言,这时既没时间也没心情打扮自己,宽大的灰色工作服一穿,耐脏又实用。虽然每天出门都要涂防晒霜,但几天下来,照样晒得黑不溜秋的。在这群人中,有很多人都没吃过这种早出晚归、扛着背着、爬高上低的苦头,抄完表后,她们的身体就像散了架。想想过去,好几个人都委屈地哭了。把表号搬到儿子作业本上
许丽芳在到供电所之前,虽然她心里已经¬做好了吃苦的准备了,但实际情况却远比想象中难得多。片区不熟,用户资料也是一片空白。不掌握用户情况,会让自己做很多无谓的工作,既影响抄表进度,又极有可能漏抄、错抄。
在抄¬新华小区时,住户杂乱不说,范围还比较大,住户先后入住,没有统一装表,电表编号非常凌乱。许丽芳只好先用儿子的数学作业本对着住户地址和电表编号,逐一抄¬回数据后,然后再输入电脑,对照作业本上的数据调整好顺序,又拿个抄¬表仪将数据从电脑里倒出来,再将调好顺序的数据重新倒回电脑进行算费,算好费后,她才拿着打好的欠费单去催费。
由于不熟悉自己的抄¬表片区,每天7:00就开始出门催费的许丽芳,从早上开始送,中午随便吃点东西后又接着送,但直到天都完全黑了,脚也走疼了,脖子也喊哑了,手里的单子却还剩下一大半,看着手中的单子,委屈、心酸、难过的滋味全部一起涌上心头,找个无人的角落,许丽芳掩面就是一场大哭。哭过了,擦擦眼泪,还得继续去做。
电筒光一照,就能看清楚
女抄¬表员王岳琼是个急性子,同事马金平常说:“我就是个急性子的人,但没想到你比我还急”。王岳琼在与杨丽搭档抄¬表的时间里,她每天早上6:30就打是电话给杨丽,告诉杨丽到某一位置找她,然后就开始一天的抄表工作,每天到晚收工时,她们都能够抄个八、九百户左右。有人问她,你去那么早抄¬表不怕遇上什么坏人吗?她说,没事,太早了就抄城里的,6:30的时候城里已经¬有很多人了,那个时候比较好看表,电筒光一照上去,就能看个就清清楚楚,白天由于周围光线太亮,反而不太好看。杨丽常说,跟着岳琼姐抄¬表,从来不怕在抄表时限内完不成工作。
要说王岳琼这个急性子,在所里是出了名的,所长资树良说:“只要告诉她所抄的片区
某某家停电,她起身就走。”每次有客户反映问题时,她都会直到解决问题后才放得下心。在抄¬完表回到所里核对时,只要发现有漏抄¬的,她绝对留不到第二天才去处理,常常是把孩子接回家吃过饭后,就又出去把抄漏的表抄¬完。
抄表员往往还肩负着帮用户换坏表、处理小故障的责任,这就要求她们必须学习用电管理相关知识,掌握基本的维修技能。王岳琼说,自己第一次帮用户换完表从梯子上下来,已经¬是满头大汗了。
客服中心共有抄表员35人,他们负责江油城区、“二马厚”、武都、含增等乡镇片区方圆80余公里18万余用户的用气、用水抄表工作。抄表员在每月的上旬都严格按照规定时间抄表、下通知单,在下旬要对自己所抄管的辖区进行催费。每个月的大多数的时间里都穿梭在大街小巷,走街串户,风雨无阻,年复一日的重复着抄表、送水、气费明细清单、催缴水、气费,关、开水、气这些简单而枯燥的事情。这个看起来平凡的工作,抄表员却要默默的面对辛劳和压力,以超常的责任心和强烈的爱岗敬业精神,克服多种困难,用恒心、诚心、热心、耐心和责任心,保质保量的完成自己的工作。
为使水气收费工作与中心拓展代理电费收取同步,每个月的抄表工作都是时间紧,任务重。面对挑战,中心抄表员工没有向困难低头,而是用积极向上的心态去应对工作任务。为了能更好地掌握管辖区内每个表箱、设施的具体地点和管网范围,中心用户管理部和各营业所管理人员带领所属抄表人员深入各个片区实地考察,对辖区内各个居民小区的用户进行走访,逐一核查住址、楼栋、门牌号和联系电话,建立完善了用户档案,新添写了用户通讯录、联系用户手册,为及时、准确抄表打下了基础。如今,中心每个抄表员都是责任片区活地图,每每提到哪个偏僻的小巷、乡村小路,哪个不知名的小企业、小村落以至于具体到哪个居民家,都能如数家珍。
每月抄表期间,抄表员都要披星戴月,用一种高度的责任感书写一户户准确的数据。抄表是一个细致工作,由于抄表的环境各异,有的楼栋防盗门白天进不去,抄表员只能利用千家万户在外出、工作前或者下班后去完成此项工作,有的平房居民家家都有大门,如果碰到家里没人,就要等到晚上甚至第二天补抄。有的用户家中养有恶狗,抄表员一不小心就会被狗咬„.抄表工作有辛劳,有快乐,他们用平凡演绎着不平凡,用朴实彰显绚丽,因为在他们的心中有一种积极的态度,一种责任,他们常说“如果因为怕困难就估抄,不仅会影响用户的消费行为,更重要的是会影响集团公司的社会形象。我们是辛苦点,但是水、气费能及时收回,用户能明明白白消费,我们打心眼里高兴。”
抄表人员最艰巨的工作是催欠水、气费。欠费的用户有的是忘了交费,有的是没时间交费,也有一些是恶意欠费。为了避免因欠费停水、停气给用户带来不便,我们的抄表员每月都要按时张贴欠费明细公示单,特别是对欠费金额大的用户,或习惯性欠费的用户,不管楼房再高,村子再远,抄表员都会在第一时间把催费单送到欠费用户家里,并通过电话给予特别通知,防止因用户粗心或者去了外地没有看到催费单而造成停水、停气,给用户带来生活不便和经济损失,引起不必要的纠纷。有的欠费用户表示对计量表有疑虑,但是校对完计量表无误后仍冷脸不愿交费,为了共处和谐,我们的抄表员积极的与社区、村组联系,不厌其烦地给用户讲道理、做解释,一次、两次、三次„„千言万语,以心换心,最终换来了用户的感动和支持,消除了猜疑并及时缴纳了欠费。“勤跑腿、磨破嘴”是他们工作的真实写照。战严寒、斗酷暑,再苦再累都能克服,面对工作的繁杂和辛苦,大家毫无怨言。冬季遇到雨雪天,冰冷的寒风夹带着雨雪,打在脸上,使得人睁不开眼睛,稍不留神就会摔个仰面朝天。在这样的天气里对所有出行的人来说都是一种身体和耐力考验。我们的抄表员不畏寒风刺骨,不畏路面泥泞湿滑,顶寒风冒雨雪行进在城市的大街小巷和乡村的田坎、山坡上,到单位、到社区楼栋、到村子挨家挨户抄表、送催费单,裤子湿透,手脚冻僵。每个抄表员最常说的一句话就是:如果多休息一分钟,我的工作就有可能完不成,不能因为我一个人完不成而影响整体水、气费的回收率。寒来暑往,中心抄表员负责的18万多户水、气用户每个月都是月清月结。
秉承“服务于民、便利于民、以人为本、优质服务”为宗旨,全方位为用户提供优质、高效、快捷的便民服务的理念深深地植根在我们的抄表员心中。为用户提供耐心、细致、周到的服务是他们应尽的职责。就是这么一群朴实、无私、默默无闻、辛勤耕耘的人,他们在部门管理人员的带领下,齐心协力,做到“不漏一表、不落一户、抄表到户、催费到家”,为实现水、气费的“颗粒归仓”辛苦努力,他们是我们心中最尊敬的人。
第五篇:抄表班安全培训心得
抄表班安全培训心得
通过对《安全职责》、《习惯性违章》、《营销风险与防范》、《高处作业》、《农村低压电网剩余电流动作保护器知识》等课件的学习,我主要有以下几点心得:
1、安全生产不是口号,这是我们电力工作者每时每刻都能听到或者看到的警句。但是这不仅仅是个口号,更是我们工作的第一准则,是我们人身安全保障的唯一措施,不能因为以前的安全就忽略了以后的危险。忘记了这个准则,就是把自己加上作料送到“电老虎”的笼子里。这也是造成事故的主要原因。
2、提高安全素质抓安全生产必须抓好人的安全文化素质、安全思想行为的教育和提高。
3、从多方面来提高员工的安全意识。安全工作只有起点,没有终点,全体员工要互教互学,取长补短,共同提高。
4、养成良好的安全操作习惯,杜绝习惯性违章,敢于同身边的不安全行为较真。每位员工在日常工作中做到相互监督、相互提醒,及时消除安全隐患。
5、贯彻落实安全工作规程,严格按照有关安全规章制度作业。把安全工作规程落到实处,结合实际情况严格要求,时刻铭记“安全是天,安全是命,安全就是一切”。
6、加强事故案例学习,吸取教训,总结经验。针对牵引供电各项事故案例进行系统的学习,吸取血与泪的沉痛教训。将各项事故案例结合到实际工作中,遇到可能出现的问题或漏洞的环节结合个人经验特别注意,加强监护,做好自控、他控、互控,防范事故于未然。作业中时刻注意个人安全防护,绝不冒险作业,绝不违章作业,绝不马虎,绝不敷衍,绝不存在侥幸的心理。禁止疲劳作业,不蛮干、瞎干、死干。作业过程中,严格要求自己,不做工作无关的事情,专心作业,呼唤应答,绝不闲谈,听从指挥,恪尽职守。